CA Syringe Filter

  CA Syringe Filter

 

 

          

 

Product Description:

 

 

 

The Cellulose Acetate syringe filter is well suited for maximum sample recovery such as tissue culture media preparation, sterile or non-sterile filtration and clarification of biological fluids, protein and enzyme filtrations, hybridization buffers, and other aqueous solutions.

 

The sterile Cellulose Acetate (AS) or with a glass fiber prefilter (ASG) is recommended to filter probe solutions.  The Cellulose Acetate (A) series syringe filters are designed to sterilize and remove particulates from proteinaceous samples.  Due to the extremely low holdup volume the negligible protein-binding characteristics, these syringe filter units are ideal for applications requiring maximum sample recovery from a standard or presterilized syringe filter.

 

The membrane filter is CA Cellulose Acetate, which eliminates the possibility of "popping" the filter.  See CA Cellulose Acetate for a detailed description of the membrane in the filters.  The 17AG (17mm), 25ASG (25mm), 30AAG (30mm) syringe filters contain a 1.0 micron borosilicate glass prefilter and the CA Cellulose Acetate membrane filter specifically designed to combine high throughputs and maximum sample recovery when filtering or sterilizing viscous proteineceous solutions.  The prefilter and membrane are contained in the acrylic housing without adhesives.

 

 

 

Features and Benefits:

 

 

 

l         Hydrophilic property

 

l         Low binding filter

 

l         Strength, uniform pore size

 

 

Technical Specification:

 

Filter    Filter

 

3A

 

3AS

 

17A

 

17AG

 

25ASG

 

30A

 

30AG

 

Cellulo   Cellulose  Acetate

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Boros   Borosilicate  Glass Prefiler

 

 

 

 

 

 

 

Yes

 

Yes

 

 

 

Yes

 

Steril(    Sterile (*Gamma irradiation)

 

 

 

Yes

 

 

 

 

 

Yes

 

 

 

 

 

Autocl    Autoclavable

 

Yes

 

Yes

 

Yes

 

Yes

 

 

 

Yes

 

Yes

 

Housin   Housing(PP Polypropylene)

 

Nylon

 

Nylon

 

pp

 

pp

 

Acrylic

 

pp

 

pp

 

Filter di  Filter diameter (mm)

 

3

 

3

 

17

 

17

 

25

 

30

 

30

 

Filtrat     Filtration area (cm2 )

 

0.1

 

0.1

 

1.4

 

1.4

 

4.1

 

4.8

 

4.8

 

Holdup   Holdup volume (uL)

 

<3

 

<3

 

<15

 

<15

 

<60

 

<60

 

<60

 

volume   Sample volume (mL)

 

<1

 

<1

 

<12

 

<18

 

<150

 

<120

 

<180

 

Maxim   Maximum Operating  Temp     Temperature

 

135°C

 

135°C

 

180°C

 

180°C

 

55°C

 

180°C

 

180°C

 

Maxim   Maximum Operating  

 

Press     Pressure (psi)

 

75 psi

 

75 psi

 

130 psi

 

130 psi

 

75 psi

 

130 psi

 

130 psi

 

 

Application:

 

 

 

l         Sterilize biological fluids, serum or media additives, 3AS, 25AS, 24ASG.

 

l         Sample preparations of aqueous solutions, 3A, 17A OR 30A.

 

l         Sample preparation of protein-based HPLC solutions, 3A, 17A.

 

l         High throughput, low binding filter units for non-sterile aqueous filtrations, 30A.

 

l         Filtrations of tissue culture media, 25ASG or 30AG.

 

l         High throughput for sterile or non-sterile clarification of even the most viscous proteinaceous Solutions, 25ASG or 30AG.

 